Cino HB2110 Manual do Utilizador Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 51
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
Configure Your FuzzyScan
2-5
Symbology Reading Control
i Code 39/Code 32 Settingi
PROGRAM M_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Code 39 Family Setting
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Select Standard Code 39 as primary format
Select Full ASCII Code 39 as primary format
Select Code 32 (Italian Pharmaceutical) as primary format
Disable start/stop symbol transmission
Enable start/stop symbol transmission
Disable Code 32 leading A transmission
Enable Code 32 leading A transmission
Disable MOD 43 check digit verification
Enable MOD 43 check digit verification
Disable check digit transmission
Enable check digit transmission
Disable RS WIDE Code 39
Enable RS WIDE Code 39
0
1
2
3
4
5
6
7
8
9
A
B
C
Code 39 Min. Length
SS
MS
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will
terminate this selection automatically.
FIN
(2 digits)
Code 39 Max. Length
SS
MS
Default (99)
99-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will
terminate this selection automatically.
FIN
(2 digits)
Selecting Full ASCII Code 39 disable Code 32 (both options may not be enabled at the same time). Standard Code 39 and Full ASCII Code 39 may be enabled at
the same time, and Code 32 and standard Code 39 may be enabled at the same time.
Vista de página 12