Configure Your FuzzyScan
2-31
[Data Formatter]
Scan “Formatter Control” and set bar code symbology to “08”.
Scan 1st Insertion” and set the identified position to “06”, then
inserted characters to “09” (Hex Code of TAB), “53” (Hex Code
of S), “4E” (Hex Code of N).
Scan “2nd Insertion” and set the identified position to “12”, then
inserted character to “09”. In the final, you must scan “FIN
(Finish) code to terminate this selection.
Scan “3rd Insertion” and set the identified position to “16”, then
inserted character to “09”. In the final, you must scan “FIN
(Finish) code to terminate this selection.
[Data Replacer]
Scan “Replacer Control” and set bar code symbology to “08”.
Scan “1st Replacement” and set the identified position to “00”,
then replaced character to “41” (Hex Code of A).
[Data Organizer]
Scan “Organizer Control” and set bar code symbology to “08”.
Scan “1st Organization” and set the identified position to “16”,
then set the data transmission to “0” (forward).
Scan “2nd Organization” and set the identified position to “17”,
then set the data transmission to “1” (backward).
Scan “END” (Exit) to terminate the programming.
[Important Notice]
Please note that Condensed DataWizard will follow the preset
working flow as below:
Verifier Formatter Replacer Organizer
So when you set the identified position in Data Organizer, you
must consider the inserted data which you already set via Data
Formatter.